Sis programming and control, Connection options, Command (see – Extron Electronics DMP 64 User Guide User Manual

Page 98

Advertising
background image

SIS Programming
and Control

This section describes SIS programming and control of the DMP 64, including:

Connection Options

Host-to-device Communications

Command and Response Table for Basic SIS Commands

Command and Response Tables for DSP SIS Commands

Special Characters

Connection Options

The DMP 64 Digital Matrix Processor can be remotely connected via a host computer or
other device (such as a control system) attached to the rear panel RS-232 port or LAN
port, or the front panel USB Config port.
The DMP 64 can be set up and controlled using SIS commands, embedded web pages,
or DSP Configurator software. See

Installation

on page 5 for pin assignments

and details on the configuration and control port connections. For information on
DSP Configurator, see

DMP Software

on page 14, and for the embedded web pages,

see

HTML Operation

on page 120.

SIS commands can be executed using the Extron Electronics DataViewer program, found
on the Software Products DVD included with the product.
DMP 64 RS-232 protocol:

• 38400 baud

• no parity

• 1 stop bit

• 8 data bits

• no flow contro

NOTE: Both rear panel configuration ports require 38400 baud communication. This

is a higher speed than many other Extron products use. When using HyperTerminal
or a similar application, make sure the PC or control system connected to these
ports is set for 38400 baud.

For additional details on connecting the RS-232 port, see

RS-232 Ports

on page 93.

USB port details:
The Extron USB driver must be installed before the USB port can be used (see

Install the

USB Driver

on page 17).

LAN port defaults:

DMP 64 IP address: 192.168.254.254

gateway IP address: 0.0.0.0

subnet mask: 255.255.0.0

DHCP: off

DMP 64 • SIS Programming and Control

92