Symbol definitions, Special characters – Extron Electronics DMP 64 User Guide User Manual

Page 110

Advertising
background image

Symbol definitions

]

=

CR/LF (carriage return/line feed) (hex 0D 0A)

}

=

Carriage return (no line feed, hex 0D)
(use the pipe character, | , for Web browser commands)

=

Space character

|

=

Pipe (vertical bar) character

E

=

Escape key (hex 1B) (use

W instead of Esc for Web browsers)

X6)

= Gain and trim control or mix-point select

See the tables on page 107.

X6!

= Level value;

mix-point gain

(

c

)

, and

post-mixer trim

(

d

)

See the table on pages 109, 110, and 111.
-35 dB to + 25 dB, (1698 to 2298 ) in

0

.1 dB increments.

NOTE: Post-mixer, –12 dB to +12 dB (1928 to 2168) only.

X6@

= Mic/line gain

(

a

)

level value

See the table on pages 112, 114, and 115.

18

.

0

 dB to +

80

 dB, (1868 to 2848 ) in

0

.1 dB increments.

X6#

= Level value:

pre-mixer gain

(

b

)

, and

output volume

(

e

)

See the table on pages 116, 117, 118, and 119.

–100.0 dB to +12.0 dB, (1048 to 2168) in 0.1 dB increments.

NOTE: Output volume, –100.0 dB to +0.0 dB (1048 to 2048 ) only.

X6$

= Mute status

0

= unmute

1

= mute

X6%

= Group master group number

01 – 32

X6^

= Group fader setting

dB value, in 0.1 dB increments using negative numbers but not decimal places.

The valid range depends on the type of gain block that is assigned to the group
number (

X6%

) specified in the command:

a

= –

180

to

800

(–

18

.

0

 dB to +

80

.

0

 dB)

b

= –1

000

to

120

(–

100

.

0

 dB to +

12

.

0

 dB)

c

= -

350

to

250

(-

35

.

0

 dB to +

25

.

0

 dB)

d

= –

120

to

120

(–

12

.

0

 dB to +

12

.

0

 dB)

e

= –

1000

to

000

(–

100

.

0

 dB to +

0

.

0

 dB)

NOTE: Leading zeros are ignored.

X6&

= Group fader increment

dB value, in

0

.

1

 dB increments, to raise or lower a group fader

X6*

= Group fader soft limit

dB value, in

0

.

1

 dB increments. The valid range

X6^

must be within the range

for the gain block grouped in

X6%

.

X6(

= Group type

6 = gain

12 = mute

X7)

= Personal Identification Number (PIN)

Four numeric digits, default = 0000

X7!

= Protected configuration status

0

= no protected configuration saved

1 = protected configuration saved

Special Characters

The HTML language reserves certain characters for specific functions. The device will not
accept these characters as part of preset names, the device name, passwords, or locally
created file names.
The DMP 64 rejects the following characters:
{space (spaces

are OK for names)} + } ~ , @ = ‘ [ ] { } < > ’ “ ; : > \ ?

DMP 64 • SIS Programming and Control

104

Advertising