Programming guide, Section) or the matrix switchers – Extron Electronics MTPX Plus Series User Guide User Manual

Page 92

Advertising
background image

Command/Response Table for SIS Commands (continued)

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Names (continued)

Write input name

EX*

,

X2$

NI

}

Nmi

X*

,

X2$]

Example:

E

1

,

Podium camNI

}

Nmi01

,

Podium cam

]

Name input 1 “Podium cam”.

Read input name

EX*

NI

}

X2$]

Write output name

EX@

,

X2$

NO

}

Nmo

X@

,

X2$]

Example:

E

1,Main PJ1NO

}

Nmo01,Main PJ1

]

Name output 1 “Main PJ1”.

Read output name

EX@

NO

}

X2$]

I/O Grouping

NOTE

:

The group that is assigned in each of the following I/O grouping commands (

X2^

) must be 1, 2, 3, 4, or 0 (not grouped).

Write input grouping

EX2^

1

X2^

2

...

X2^

n

I

}

Gri

X2^

1

X2^

2

X2^

3

...

X2^

n

]

n = the maximum number of inputs.
Each

X2^

entry is the group

number assigned to an input
position, starting from input 1.

Example: MTPX Plus 168

E4013300004440443I

}

Gri4013300004440443

]

(see below)

01

Input:

Gri

Response #s = group:

Input 1 in group 4

02 03 04 05 06 07 08 09 10 11 12

4 0 1 3 3 0 0 0 0 4 4 4

13 14 15 16

0 4 4 3

Input 2 not grouped Input 12 in group 4

Input 1 - Group 4, Input 2 - Group 0
(not grouped), ... Input 16 - Group 3.

NOTE

:

You must enter an

X2^

value for each input in your matrix size, such as 32 inputs for an MTPX Plus 3216.

Write output grouping

E

X2^

1

X2^

2

...

X2^

n

O

}

Gro

X2^

1

X2^

2

X2^

3

...

X2^

n

]

n = the maximum number of outputs.
Each

X2^

entry is the group number

assigned to an output position, starting
from output 2.

Read input grouping

EI

}

X2^

1

X2^

2

X2^

3

...

X2^

n

]

n = the maximum number of inputs.
Each

X2^

entry is the group number

assigned to an output position, starting
from input 1.

Example: MTPX Plus 1616

EI

}

11113300004440444

]

(see below)

01

Input:

Response = group:

Input 1 in group 1

02 03 04 05 06 07 08 09 10 11 12

1 1 1 3 3 0 0

0

0

4 4 4

13 14 15 16

0 4 4 4

Input 8 not grouped Input 12 in group 4

Read output grouping

EO

}

X2^

1

X2^

2

X2^

3

...

X2^

n

]

n = the maximum number of outputs.

Save, recall, and directly write global presets

NOTE

:

If you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.

Save current configuration as a
global preset

X2#

,

Spr

X2#]

Command character is a comma.

Example:

8,

Spr08

]

Save current ties as preset 8.

Recall a global preset

X2#

.

Rpr

X2#]

Command character is a period.

Example:

5.

Rpr05

]

Recall preset 5, which becomes the
current configuration.

NOTE:

X@

= Output number

01 – (maximum number of outputs for your model)

X*

= Input number

01 – (maximum number of inputs for your model)

X2#

= Global or room preset #

01 - 32, 10 maximum for a room preset

X2%

= Room # (for room presets)

10 max. (each can have up to 10 presets (

X2#

s) assigned)

X2^

= Group #

1 through 4 groups (0 = no group)

MTPX Plus Series • Programming Guide

86