Danger, Warning, Caution – Elmo Rietschle L-BV3 User Manual

Page 12

Advertising
background image

Installation

610.444430.40.000

12 / 32

© Gardner Denver Deutschland GmbH

service life of the pump-motor unit, this
value may not be exceeded.
Generally, this value can be adhered to
without a special foundation or a special
base plate.
The points on the unit for measuring the
vibration speed are shown in Fig. 2, Pg. 12.

Fig. 2: Points for measuring the vibration speed


Securing:

Screw the feet of the pump-motor unit to the
surface with suitable mounting elements.

Proceed as follows:

 The feet of the pump-motor unit are

provided with mounting holes.

 Select the suitable screw type.
 Screw the feet of the pump-motor unit to

the surface with the screws.
When doing so, be sure to provide all
mounting holes with screws!



6.2

Electrical connection (motor)

DANGER

Electrical danger!
Malpractice can result in severe injuries and
material damage!

DANGER

Electrical danger!
The electrical connection may be carried out
by trained and authorized electricians only!

DANGER

Electrical danger!
Before beginning work on the unit or system,
the following measures must be carried out:
 Deenergize.

 Secure against being switched on again.

 Determine

whether

deenergized.

 Ground and short-circuit.

 Cover or block off adjacent energized parts.

DANGER

Electrical danger!
Replace loose connections, singed or burned
cables immediately!

DANGER

Electrical danger!
Depending on the charging state of the
capacitors, a residual voltage may be present
on the terminals in the terminal box.
After opening the terminal box cover, it must
be ensured that the capacitors are completely
deenergized:
 Measure the voltage at the corresponding

jumpers (see the circuit diagram in the
terminal box).

 Dissipate the residual voltage with suitable

means if necessary.

The capacitors must be completely
deenergized.

WARNING

Danger due to gauge pressure and vacuum!
Danger due to escaping fluid!
Before beginning work on the unit or system:
Interrupt supply of operating liquid.
Bleed lines and vacuum pump/compressor
(depressurize).

CAUTION

Incorrect connection of the motor can lead to
serious damage to the unit!