Servicing

610.444430.40.000

24 / 32

© Gardner Denver Deutschland GmbH

10 Servicing

WARNING

Improper use of the machine can result in
serious or even fatal injuries!
Have you read the safety precautions in
Chapter 1, "Safety", Pg. 3 f.?
Otherwise you may not carry out any work with
or on the machine!

WARNING

Improper use of the unit can result in
serious or even fatal injuries!
All maintenance work on the pump-motor unit
must always be performed by the Service
Department!
Inquire with the Service Department!

DANGER

Electrical danger!
Before beginning work on the unit or system,
the following measures must be carried out:
 Deenergize.

 Secure against being switched on again.

 Determine

whether

deenergized.

 Ground and short-circuit.

 Cover or block off adjacent energized parts.

DANGER

Electrical danger!
Replace loose connections, singed or burned
cables immediately!

DANGER

Electrical danger!
Depending on the charging state of the
capacitors, a residual voltage may be present
on the terminals in the terminal box.
After opening the terminal box cover, it must
be ensured that the capacitors are completely
deenergized:
 Measure the voltage at the corresponding

jumpers (see the circuit diagram in the
terminal box).

 Dissipate the residual voltage with suitable

means if necessary.

The capacitors must be completely
deenergized.

WARNING

Danger due to gauge pressure and vacuum!
Danger due to escaping fluid!
Before beginning work on the unit or system:
 Interrupt supply of operating liquid.

 Bleed lines and vacuum pump/compressor

(depressurize).

WARNING

Danger from rotating external fan of unit!
It is prohibited to remove the fan guard!

WARNING

Danger from rotating impeller of unit!
It is prohibited to remove the vacuum
pump/compressor cover and the housing!

WARNING

Danger of burns and scalding from hot
surfaces of the pump-motor unit and from
hot fluids!
Do not touch during operation!
Allow to cool after shut-down!


10.1 Maintenance

The pump-motor unit is largely maintenance-
free.
If water containing lime is used as the
operating liquid, the operating liquid must be
softened or the pump-motor unit must be
decalcified at regular intervals.
Refer to the following table: