Technical Data

610.444430.40.000

8 / 32

© Gardner Denver Deutschland GmbH

Operating-liquid temperature:

max. +40 °C

max. +104 °F

min. +5 °C

min. +41 °F

Nominal value:

+15 °C

+59 °F


Ambient temperature:

max. +40 °C

+104 °F

min. +5 °C

+41 °F



Pressures

Min. inlet pressure p

1 min

:

Depending on the type and temperature of the
operating liquid.
During vacuum operation without cavitation
protection (cavitation protection hole closed):

5 kPa

0.725 psi

It may not be dropped below to prevent
damage due to cavitation!
Damage due to cavitation are purposely
disregarded if the minimum inlet pressure is
3.3 kPa [0.479 psi].
The specified values apply to the following
conditions:

 Operating

liquid:

Water at +15 °C [+59 °F]

 pumped

gases/vapors:

dry air at +20 °C [68 °F]

They are higher the higher the temperature
and the higher the vapor pressure of the
operating liquid used.
During vacuum operation with cavitation
protection (cavitation protection hole open):
max. achievable vacuum, i.e. complete
throttling
The following generally applies: The higher the
temperature, the lower the intake capacity, i.e.
the higher the minimum achievable inlet
pressure.

Max. discharge pressure p

2 max

during

vacuum operation:

110 kPa abs.

16.0 psia

This value applies, provided the rated
operating-liquid flow rate is adhered to.

Max. discharge pressure (differential
pressure) p

2 max

during compressor

operation (at inlet pressure p

1

= 101.3

bar abs. [14.7 psia]):

60 kPa

8.70 psi

This value applies, provided the rated operating-
liquid flow rate is adhered to.

Max. permissible pressure in the pump-
motor unit p

int max

during compressor

operation:

300 kPa abs.

43.5 psia

If higher pressures can occur in the system, then
corresponding protective devices must be provided.


Max. pre-pressure of the operating liquid

300 kPa abs.

43.5 psia

When the permissible operating liquid pressure is
exceeded, too much liquid enters the vacuum
pump/compressor. Damage can occur.



Liquid quantities

Nominal operating-liquid flow rate
(with dry air extraction and with water at 15 °C
[59 °F] as operating liquid)

0.65 l/min 0.172 gal (US)/min 0.143 gal (UK)/min

(0.039 m³/h)

(1.38 ft³/h)


Max. filling quantity for operating liquid at a
standstill

0.200 l

0.053 gal (US) 0.044 gal (UK)

Repeated switching on of the pump-motor unit
in the flooded state can result in damage.


Maximum permissible quantity of water
entrained via the inlet connection

3.9 l/min

1.03 gal (US)/min 0.858 gal (UK)/min

If larger quantities can occur, a separator must be
installed upstream on the inlet side.