background image

Operating modes

© Gardner Denver Deutschland GmbH

9 / 32

610.444430.40.000

4 Operating

modes

The pump-motor unit can function in several
different operating modes.
These differ in how the pump-motor unit is
supplied with operating liquid:

 Self-priming

operation

 Operation with operating-liquid feed:

Non-automatic operation

Automatic operation



4.1 Self-priming

operation

In this operating mode the pump-motor unit
automatically sucks in the operating liquid.
The operating-liquid flow rate is automatically
adjusted.

See Fig. 4, Pg. 17.


4.2

Operation with operating-liquid feed

In this operating mode the pump-motor unit
DOES NOT automatically suck in the operating
liquid.
A certain volume flow ("nominal operating-
liquid flow rate") or pre-pressure must be set
for the operating liquid.


Here the following additional distinctions are
made:

Non-automatic operation

In this case the operating liquid feed is
switched on and off manually with a stop valve.

See Fig. 6, Pg. 19.

Automatic operation

In this case the operating liquid feed is
switched on and off by a solenoid valve. The
solenoid valve is dependent on the motor
operating mode:

 Motor/pump-motor unit switched on:

Valve open.

 Motor/pump-motor unit switched off:

Valve closed.

See Fig. 7, Pg. 19.

NOTICE

The following is dependent on the operating
mode:
 when and how the pump-motor unit must

be filled with operating liquid the first time,

 how the pump-motor unit is put into

operation.

The specifications for this are contained in
Chapter 6, "Installation", Pg. 11ff., and
Chapter 7, "Commissioning", Pg. 16ff.