10.2 Repairs/troubleshooting

Fault

Cause

Remedy

Carried out by

Motor does
not start, no
running
noise.

Interruption of the
power supply,
with single-phase
model in one
cable, with two-
phase model in at
least two cables.

Check fuses, terminals and cables for open
circuit. Eliminate open circuit.

Electrician

One power
supply lead
interrupted.

Check fuses, terminals and cables for open
circuit. Eliminate open circuit.

Electrician

Free shaft by turning.
See Chapter 10.1, "Maintenance", Pg. 24.

Operator

Decalcify vacuum pump/compressor.
See Chapter 10.1, "Maintenance", Pg. 24.

Operator

Drain and clean vacuum pump/compressor if
necessary.
See Chapter 10.1, "Maintenance", Pg. 24.

Operator

Impeller is
jammed.

Check and correct impeller gap setting if
necessary.

Service

Impeller
defective.

Replace impeller.

Service

Motor does
not start,
humming
noises.

Motor bearings
defective.

Replace motor bearings.

Service