3 technical data, Notice – Elmo Rietschle L-BV3 User Manual

Page 7

Advertising
background image

Technical Data

© Gardner Denver Deutschland GmbH

7 / 32

610.444430.40.000

3 Technical

Data

3.1 Mechanical

data

Weight

Type

Weight

approx.

[kg]

approx.

[lbs]

2BV3151 9

19.8

Higher weights are possible with special
models.

Minimum distances for heat dissipation

Type

Minimum distance from

fan guard to adjacent surface

[mm]

[inches]

2BV3151 20

0.787


Noise level

Measuring-surface sound-pressure level
according to EN ISO 3744 measured at a
distance of 1 m [3.28 ft] with moderate
throtteling (8 kPa abs. [1.16 psia]) and lines
connected.

Type

1-m measuring-surface sound

pressure level L [dB (A)

at 50 Hz:

at 60 Hz:

2BV3151 70 70


Operating speed

See rating plate.

NOTICE

Exceeding of the operating speed will
negatively affect the operating behavior of the
pump-motor unit:
 higher

noise

emissions

 stronger

vibrations

 shorter grease consumption time

 reduced bearing change interval

To prevent damage due to excessively high
speeds, it may be necessary to request the
limit speed

(inquire with the Service

Department).

Tightening torques

The values specified here for tightening
torques apply unless other values are
indicated.

Tightening torques

for screw connections

(pipe-connections)

Thread

[Nm]

± 10 %

[ft lbs]
± 10 %

G⅛ 4.5 3.32
G⅜ 16 11.8

Tightening torques

for electrical connections

(terminal board-connections)

Thread

[Nm]

± 10 %

[ft lbs]
± 10 %

M4 1.0 0.738
M5 2.2 1.62

These values for electrical connections applies
to all terminal board connections with the
exception of modular terminal blocks.)

Tightening torques

for electrical connections

(modular terminal blocks)

Thread

[Nm]

± 10 %

[ft lbs]
± 10 %

M3 0.6 0.443

(These values for electrical connections apply
to all modular terminal blocks.)


3.2 Electrical

data

See drive motor rating plate.


3.3 Operating

conditions

Temperatures

Temperature of pumped gases/vapors:

max. +110 °C

max. +230 °F

At higher fluid temperatures, measures must
be taken on the system to prevent burns, e.g.
mount separating safety device (cover).
In addition, we also recommend one of the
following measures at temperatures > 80 °C
[> 176 °F]:

 Increasing the operating-liquid flow rate by

up to twice the rated liquid flow rate (cooling
circuit)

 Use of a series capacitor

Advertising