3. Installation


Make sure that all accessories and parts listed above are present in the scope of delivery. An Ethernet cable
is required for camera operation. This Ethernet cable must meet UTP Category 5 (CAT 5) specifications and
must not be longer than 100 metres.

3.1 Power supply


Before starting installation, ensure that the mains voltage and the rated voltage on the power supply unit are
identical.

A two-pin plug connection is used for supplying the
camera with power. The power supply unit is delivered
without the two-pin plug as standard. The plug is
already attached to the power supply socket of the
camera.

The positive terminal on the power supply unit is
marked accordingly. Connect the two wires from the
power supply unit (secondary side, 12 VDC) to the
power supply plug in the camera.

The plug can be removed from the socket to do this.

3.2 Cable layout


Cables can be laid at the side (visible) or through the bottom (hidden). A cable connection is attached to the
housing to protect against moisture. Screw this cable connection fully into the opening on the side or bottom of
the housing. The second opening is sealed using the pre-installed plug on the bottom.