10464A ECL Data Pod (Terminated)

Output type

10H115 with 330

Ω pulldown, 47 Ω series

Maximum clock

200 MHz

Skew (note 1)

Typical < 1 ns; worst case = 2 ns

Recommended lead set

Agilent 10474A

10465A ECL Data Pod (Unterminated)

Output type

10H115 (no termination)

Maximum clock

200 MHz

Skew (note 1)

Typical < 1 ns; worst case = 2 ns

Recommended lead set

Agilent 10347A

10H115

47

330

-5.2V

10H115

10469A 5 Volt PECL Data Pod

Output type

100EL90 (5V) with 348

Ω pulldown to ground and 42 Ω in series

Maximum clock

300 MHz

Skew (note 1)

Typical < 500 ps; worst case = 1 ns

Recommended lead set

Agilent 10498A

100EL90

42

348

10471A 3.3 Volt LVPECL Data Pod

Output type

100LVEL90 with 215

Ω pulldown to ground and 42 Ω in series

Maximum clock

300 MHz

Skew (note 1)

Typical < 500 ps; worst case = 1 ns

Recommended lead set

Agilent 10498A

100LVEL90

42

215

Note 1: Typical skew measurements made at pod connector with approximately 10 pF/50 k

Ω load to GND; worst case skew

numbers are a calculation of worst case conditions through circuits.

Note 2: Channel 7 on the 3-state pods has been brought out in parallel as a non 3-state signal. By looping this output back into