10473A 3-STATE 2.5 Volt Data Pod

Output type

74AVC16244

3-state enable

negative true, 38K

Ω to GND, enable on no connect

Maximum clock

300 MHz

Skew (note 1)

typical < 1.5 ns; worst case = 2 ns

Recommended lead set

Agilent 10498A

74AVC16244

10476A 3-STATE 1.8 Volt Data Pod

Output type

74AVC16244

3-state enable

negative true, 38K

Ω to GND, enable on no connect

Maximum clock

300 MHz

Skew (note 1)

typical < 1.5 ns; worst case = 2 ns

Recommended lead set

Agilent 10498A

74AVC16244

10483A 3-STATE 3.3 Volt Data Pod

Output type

74AVC16244

3-state enable

negative true, 38K

Ω to GND, enable on no connect

Maximum clock

300 MHz

Skew (note 1)

typical < 1.5 ns; worst case = 2 ns

Recommended lead set

Agilent 10498A

74AVC16244

Note 1: Typical skew measurements made at pod connector with approximately 10 pF/50 k

Ω load to GND; worst case skew

numbers are a calculation of worst case conditions through circuits.

Note 2: Channel 7 on the 3-state pods has been brought out in parallel as a non 3-state signal. By looping this output back into

the 3-state enable line, the channel can be used as a 3-state enable.

10E156

or

10E154

-5.2V

Differential
Output

1K

Data Cable Characteristics Without a Data Pod

The Agilent pattern generator data cables without a data pod provide an ECL terminated (1 K

Ω to

–5.2V) differential signal (from a type 10E156 or 10E154 driver). These are usable when received
by a differential receiver, preferably with a 100

Ω termination across the lines. These signals

should not be used single ended due to the slow fall time and shifted voltage threshold (they are
not ECL compatible).