Dialight D564-A13-001 Vigilant L864 LED Based Red Medium Intensity Beacon User Manual
Page 10
Document No.
9100-127-1733-99 Rev A
June 19, 2013
_____________________________________________________________________
_____________________________________________________________________________
Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727
Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com
10 of 14
Replacement Procedure for the Power Supply
Step 1 WARNING: Power to the Beacon must be removed prior to servicing.
Step 2 Unclip 3 tabs holding the dome down and place it out of the way (dome
is tethered to pedestal).
Step 3 Remove 3 Phillips head screws (8-32 x ¼ inch) and accompanying
lockwashers holding the Aluminum cover plate down and place it out of
the way. Be careful not to misplace the hardware and cover plate.