4.1 Lightning Protection

The Beacon incorporates protection against voltage surges (as induced by
nearby lightning strikes for example) by means of a multi stage protection circuit
utilizing the latest in arresting protective components




Section 5: Maintenance and Troubleshooting

No regularly scheduled maintenance is required for the Beacon.

General cleaning of the Dome Assembly should be done using soapy water. No
other cleaning solutions are recommended. Abrasive compounds will scratch the
Dome Assembly.

Table 1 Lists possible faults and repair procedures for the L-864 Red Beacon

Table 1 Troubleshooting

Symptom

Possible Cause

Corrective Action

Beacon does not light

No AC power



LED Failure


Power supply Failure

Verify proper AC levels from
power source thru supply
lines.

Replace LED Module


Replace power supply

Beacon does not flash Refer to controller

documentation
supplied by the
manufacturer.