Dialight D564-A13-001 Vigilant L864 LED Based Red Medium Intensity Beacon User Manual

Page 9

Advertising
background image

Document No.

9100-127-1733-99 Rev A

June 19, 2013

_____________________________________________________________________

_____________________________________________________________________________

Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727

Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com

9 of 14

Figure 5 – Beacon in Open Position


Step 5

Rotate the lamp downwards to approximately 10 degrees from the
closed position. The key should line up with the keyway on the hinge and
allow for the lamp to be pulled off of its pins.

Figure 6 – Lamp Install/Removal Position

Step 6 Slide the new lamp onto the pins to line it up. Rotate it to approximately

10 degrees from closed to again line up the keyway. Push the light
engine past the key until it clears and than rotate it back to the open
position.


Step 7

Reconnect the line and neutral wires to the terminal block, followed by
the grounding strap.


Step 8

Rotate the lamp down to the closed position and secure the two latches
to complete installation. Apply power to ensure the beacon lights up
correctly.