Dialight D1RW-C13-008 Vigilant L864 / L865 LED Based Dual Red / White Beacon User Manual

Page 11

Advertising
background image

Document No.

9100-127-1354-99 Rev B

Release Date: 10/7/2010

_____________________________________________________________________

_____________________________________________________________________________

Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727

Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com

Page 11 of 25

DIAGRAM SHOWING HOW TO SYNCHRONIZE FLASH RATES




Day/Night contact

Connect to Common for Night mode


Dim 0

Connect Dim 0 to Common to reduce light output to
30% of maximum

Dim 1

Connect Dim 1 to Common to reduce light output to
10% of maximum
Note: Dimming affects both White Strobe and Red
Beacon


Two uncommitted solid-state relay outputs are provided to indicate a fault with
the Red or White Beacon;

Red Fault A

Red Fault B


White Fault A

White Fault B


Each solid state relay is rated for up to 600V/40mA max, 20mA continuous. The
relays can either be configured to close or open when there is a fault condition,
or pulse (fail safe, at a rate of 1 Hz with a duty cycle of 50%) when all is OK by
means of the Configuration Options switch.

Sync Out

Sync In

Sync In

To Sync In of other synchronized strobes

Master Strobe

Slave Strobe

Advertising