Dialight D1RW-C13-008 Vigilant L864 / L865 LED Based Dual Red / White Beacon User Manual

Page 8

Advertising
background image

Document No.

9100-127-1354-99 Rev B

Release Date: 10/7/2010

_____________________________________________________________________

_____________________________________________________________________________

Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727

Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com

Page 8 of 25

Section 4: System Installation Recommendations for EMC and Lightning

Immunity



1: Electrically bond the shield of the Flash Head cable to ground at both ends.
Make 360-degree ground connections around the braid or foil (avoid pigtails).

2: If there is a drain-wire in the cable, connect to ground at both ends

3: Ensure the Flash Head is electrically bonded to the tower

4: Minimize loop areas by tying all cables against the tower or passing through
conduit

5: Ensure the power-supply cabinet is electrically bonded to the tower

6: Ground any spare/unused conductors in the Flash Head cable at both ends

7: Keep wiring tidy with cables performing different functions tied up separately.
Keep power, control and output cables separate. Tie up wires to minimize loop
areas.


For a detailed step by step procedure, refer to “Recommendations for
Proper Grounding to Minimize Lightning Damage” guide available at

http://www.dialight.com/assets/installation_manuals/9100127140699.pdf

Advertising