Dialight D1RW-C13-008 Vigilant L864 / L865 LED Based Dual Red / White Beacon User Manual

Page 5

Advertising
background image

Document No.

9100-127-1354-99 Rev B

Release Date: 10/7/2010

_____________________________________________________________________

_____________________________________________________________________________

Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727

Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com

Page 5 of 25

Section 2: Installation and Wiring


The Driver module should be mounted inside a grounded, metal enclosure to
provide environmental, electromagnetic interference and safety protection.

For safety, an interlock switch should be fitted to the Controller cabinet door such
that when opened, power is disconnected from the system.

A multi-conductor cable needs to be provided to connect the Driver to the Flash
Head.





















SYSTEM BLOCK DIAGRAM


Multi-way connection
cable

Flash
Head

Power In

Enclosure/Cabinet

Alarm

Outputs

Control
Signals

Advertising