Dialight D1RW-L13-008 Vigilant L866/L885 LED Based Dual Red / White Catenary User Manual

Page 12

Advertising
background image

Document No.

9100-127-1426-99 Rev D

Release Date: 10/26/2010

_____________________________________________________________________

_____________________________________________________________________________

Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727

Tel: 732.919.3119 Fax: 732.751.5778 Web: www.dialight.com

Page 12 of 25



Section 8: Configuration Option Switches

Switch


1

Selects night mode color

2

N/A

3

Selects whether fault relays pulse while system is OK

4

Selects whether fault relays open or close on fault

CONFIGURATION SWITCH SETTINGS (on Microcontroller Board)









ON

OFF

1.

White at night

Red at night

2.

Reserved

Must be set to OFF

3.

Relays pulse while system is OK

Relays do not pulse

4.

Relays open on fault

Relays close on fault



Section 9: Configuration Via Serial Port

Certain parameters may be configured via a serial port on the microcontroller
board. This allows different pulse times and duty cycles to be set up, as well as
allowing for additional monitoring capabilities. See Appendix A for more
information about the connection and protocol.