Section 17: 100-240Vac Operated Systems


When it is required to operate the system from a 100-240V mains supply, an
additional AC to 48VDC power supply is required (recommended p/n:
D1RW9004).

It is recommended that this supply be rated for at least 120W output.

If the system is to comply with FAA 150/5345-43F, certain details of this standard
should be considered when choosing the power supply.

Section
3.3.8 and 4.2.9

6kV/3000A combination-wave, transient test.

3.3.15 and 4.2.11

1.414kV/10uA leakage current test

4.2.2

+55ºC operational test

4.2.3

-40ºC operational test and -55ºC storage test