Note:

1: If conductor thickness is reduced the maximum permissible distance between
Flash Head and power supply will be reduced.

2: For maximum immunity to the effects of radiated interference and lightning, the
cable from the Control Box to Power Supply Cabinet must be shielded with the
shield bonded to ground at both ends.

FLASH HEAD TERMINAL BLOCK CONNECTION

The cable connects to the Driver by means of the terminal blocks on the DIN
Rail. The conductors connect one to one, to the corresponding terminals in the
Flash Head.

Warning:

Take care to connect correctly, as incorrect operation can cause damage to

the driver modules.