Chapter 3: operation – I-View FDMO-36XIR/27XIR/22XIR/18XIR Outdoor IR Speed Dome Camera User Manual
Page 20
![background image](/manuals/322149/20/background.png)
20
Chapter 3: Operation
S/W ADDRESS:
a.) Select <SYSTEM SETUP> in main menu
b.) Press [OPEN] button or lean to right direction of joystick to enter SYSTEM SETUP menu.
c.) Move the joystick down to S/W ADDRESS and then press [OPEN] button or lean to right
direction of joystick to enable the setup ID address by S/W ADDRESS. When the S/W
ADDRESS function is enabled; the DIP ADDRESS will be disabling automatically.
d.) Move the joystick up or down to select ID address from 0~255. If the S/W ADDRESS
enable, the function of DIP address function will automatically closed. The ID address
SETUP must via the S/W ADDRESS.
e.) Select <BACK> or <EXIT>. Press [OPEN] button to return to main menu or exit
programming menu.
f.) To change back by DIP ADDRESS order => Set S/W ADDRESS to “ - - - “. DIP
ADDRESS will automatically set as default.
S/W ADDRESS can be only set up to 63 when you want to change the S/W ADDRESS to
DIP ADDRESS, because DIP ADDRESS can be no more then 63, if S/W ADDRESS is
more then 63, there will be no response of the camera.