Castle Equalizer Edgebander User Manual

Page 25

Advertising
background image

23

Glue pot is overfilling

ƒ Check for leaks in the Control Hoses.

ƒ Check the small black and white Control Tubes for kinks and blockages.

Glue pot has no heat

ƒ Do not attempt to service the controls without guidance. Contact Castle, Inc. before

undertaking any troubleshooting of the Control Box. Attempting to service controls
without authorization will void your warranty.

ƒ The Sensor may have failed. Check the wires to the Temperature Sensor, being

careful to notice any broken wires.

Glue Temperature is too low - Poor Bonding Strength and

It strings out during application

ƒ Adjust the temperature control up by ONE number, allow 10 minutes for temperature

to stabilize, and then test.


ƒ Check Glue Pot for burned glue residue on the bottom of the pot. If excessive residue

is found then clean pot with Glue Pot Cleaner.


ƒ Check the bottom outside of the Glue Pot and the Hot Plate for glue residue. Clean if

necessary.

Glue temperature is too high - glue pot is smoking

ƒ Adjust temperature control down by ONE number, allow 10 minutes for temperature

to stabilize, and then test.

Guillotine Sticking

ƒ The Pivot may be too tight. Locate and loosen the Pivot Screw slightly, allowing for

some free play.

ƒ Cutting Wheel has become gummed up. Rotate the Wheel to a clean spot. The

Wheel should be loose enough to turn by hand. The Wheel will need to be cleaned.

ƒ Cutting Blade may be chipped. If this is the case the blade needs to be replaced.