8.4

MACHINE CALIBRATION

Saves the calibration values

Confirm

Goes back to the setup screen

Return to main screen

Reserved Setup

Dismount any wheel from the wheel balancing machine, close the spindle and the guard and press the button

1.

Open the guard, fit the calibration tool on the outside of the adapter (as shown in the figure), close the guard and

2.

press

Open the guard, fit the calibration tool on the inside of the adapter (as shown in the figure) in the same hole used

3.

for the previous spin, close the guard and press

Move the tool to the top at 12 o’clock and press the button

4.

Press the button

5.

.

R

emove

The

cAlIbRATIoN

Tool

;

peRfoRmING

A

bAlANcING

spIN

WITh

The

cAlIbRATIoN

Tool

fITTed

oN

The

INsIde

mIGhT

cAuse

seRIous

dAmAGe

To

The

INTeRNAl

lAseR

.

6. Press

to exit from the screen.