8.4
MACHINE CALIBRATION
Saves the calibration values
Confirm
Goes back to the setup screen
Return to main screen
Reserved Setup
Dismount any wheel from the wheel balancing machine, close the spindle and the guard and press the button
1.
Open the guard, fit the calibration tool on the outside of the adapter (as shown in the figure), close the guard and
2.
press
Open the guard, fit the calibration tool on the inside of the adapter (as shown in the figure) in the same hole used
3.
for the previous spin, close the guard and press
Move the tool to the top at 12 o’clock and press the button
4.
Press the button
5.
.
R
emove
The
cAlIbRATIoN
Tool
;
peRfoRmING
A
bAlANcING
spIN
WITh
The
cAlIbRATIoN
Tool
fITTed
oN
The
INsIde
mIGhT
cAuse
seRIous
dAmAGe
To
The
INTeRNAl
lAseR
.
6. Press
to exit from the screen.