GB

6 - SET-UP

6.1 - Autodiagnostics

Performs tests useful for maintenance staff.

6.2 - Autocalibration

For autocalibration proceed as follows:

Fit a wheel with steel rim of average dimensions on the shaft. Example 6” x 14” (± 1”)

Set the exact dimensions of the wheel mounted.

S

ETTING

INCORRECT

DIMENSIONS

WILL

RESULT

IN

THE

MACHINE

NOT

BEING

PROPERLY

CALIBRATED

AND

HENCE

ALL

THE

SUBSEQUENT

MEASUREMENTS

WILL

BE

INCORRECT

UNTIL

A

NEW

AUTOCALIBRATION

IS

PERFORMED

WITH

THE

CORRECT

DIMENSIONS

!!

1.

2.

- Perform a spin under normal conditions.

- Add a 60 g. sample weight (2.00 oz) on the outside in any angular
position.

- Shift the sample weight from the outside to the inside keeping the
same angular position.

- Turn the wheel until the sample weight is in the 12 o’clock position.

END OF AUTOCALIBRATION

CANCEL AUTOCALIBRATION IN ANY PHASE.