6 - set-up – CEMB USA K9 (A) User Manual
Page 15
I 0615 - 15
GB
6 - SET-UP
6.1 - Autodiagnostics
Performs tests useful for maintenance staff.
6.2 - Autocalibration
For autocalibration proceed as follows:
Fit a wheel with steel rim of average dimensions on the shaft. Example 6” x 14” (± 1”)
Set the exact dimensions of the wheel mounted.
S
ETTING
INCORRECT
DIMENSIONS
WILL
RESULT
IN
THE
MACHINE
NOT
BEING
PROPERLY
CALIBRATED
AND
HENCE
ALL
THE
SUBSEQUENT
MEASUREMENTS
WILL
BE
INCORRECT
UNTIL
A
NEW
AUTOCALIBRATION
IS
PERFORMED
WITH
THE
CORRECT
DIMENSIONS
!!
►
1.
2.
- Perform a spin under normal conditions.
- Add a 60 g. sample weight (2.00 oz) on the outside in any angular
position.
- Shift the sample weight from the outside to the inside keeping the
same angular position.
- Turn the wheel until the sample weight is in the 12 o’clock position.
END OF AUTOCALIBRATION
CANCEL AUTOCALIBRATION IN ANY PHASE.