Introduction, Attention installer, General description – ClimaCool SHC onDEMAND 30, 50, 70, 85 Manual User Manual
Page 3: Safety, Danger
 
1
www.climacoolcorp.com
Introduction
General Description
The SHC onDEMAND eliminates the need to have separate 
equipment for heating and cooling while saving installation 
costs thus reducing the physical footprint and overall 
operating costs. It Ƥ
demands without using inter-module/external header 
isolation valves, controls, associated logic, piping or wiring 
while allowing any module to be indexed for heating or 
cooling regardless of its position in the bank.
Safety
Throughout this manual warning, danger, caution and 
attention notices appear. Read these items carefully 
before attempting any installation, service or 
troubleshooting of the equipment. All labels on 
unit access panels must be observed.
DANGER: Immediate hazardous situation which, if not 
avoided, will result in death or serious injury. 
WARNING: Potentially hazardous situation which, if not 
avoided, could result in death or serious injury.
CAUTION: Potentially hazardous situation or an unsafe 
practice which, if not avoided, could result in minor or 
moderate injury, product or property damage. 
ATTENTIONǣƤ
ǡ
maintenance information which is important, but not 
hazard-related.
*(<;065
t &YDFTTJWF$IMPSJOF 6OEJTTPMWFE4PMJETBOE
PUIFSJNQSPQFSXBUFSRVBMJUZDPOEJUJPOT
WILL DAMAGEUIFJOUFSOBMIFBUFYDIBOHFSBOE
WILL VOID YOUR WARRANTY!
DANGER
 (OHFWULFVKRFNKD]DUG
 0D\UHVXOWLQLQMXU\RUGHDWK
 'LVFRQQHFWSRZHUVXSSO\LHV
EHIRUHVHUYLFLQJ
 5HIHUVHUYLFLQJWRTXDOLILHG
VHUYLFHSHUVRQQHO
 5LVTXHGHFKRFpOHFWULTXH
 5pVXOWDWGHPDLGDQVGRPPDJHV
RXODPRUW
 'HEUDQFKHUDYDQWGҋHQWUHSUHQGUH
OHGpSDQQDJHGHOҋDSSDUHLO
 &RQVXOWHUXQUpSDUDWHXUTXDOLILH
SRXUOHGpSDQQDJH
DANGER
&$87,21
$77(17,21
 8QLWWREHVHUYLFHGE\TXDOLILHG
SHUVRQQHORQO\
 5HIULJHUDQWV\VWHPXQGHU
SUHVVXUH
 5HOLHYHSUHVVXUHEHIRUHXVLQJ
WRXUFK
 5HFRYHUUHIULJHUDQWDQGVWRUHRU
GLVSRVHRISURSHUO\
 &RQILHUODPDLQWHQDQFHiXQ
WHFKQLFLHQTXDOLILH
 /HV\VWpPHIULJRULILTXHVRXV
SUHVVLRQ
 'pFRPSULPHUDYDQWGҋH[SRVHUi
ODIODPPH
 5pFXSHUpUOHIULJRULJHQHHWOH
VWRFNHURXOHGpWULUH
FRUUHFWHPHQW
RECOVER
REFRIGERANT
WARNING
To avoid the release of refrigerant into the atmosphere, 
the refrigerant circuit of this unit must be serviced only by 
WHFKQLFLDQVZKRPHHWORFDOVWDWHDQGIHGHUDOSUR¿FLHQF\
requirements.
All refrigerant discharged from this unit must be recovered 
WITHOUT EXCEPTION. Technicians must follow industry 
accepted guidelines and all local, state and federal statutes for 
the recovery and disposal of refrigerants.
If a compressor is removed from this unit, system refrigerant 
circuit oil will remain in the compressor. To avoid leakage of 
compressor oil, the refrigerant lines of the compressor must 
be sealed after it is removed.
WARNING
This unit contains HFC-(R410A), an azeotropic mixture of R-32 (Difluoromethane) and R-125 (Pentafluoroethane). 
DO NOT VENT HFC-(R410A) to the atmosphere. The U.S. Clean Air Act requires the recovery of any residual 
refrigerant. Do not use R-22 service equipment or components on R410A systems.
WARNING!
WARNING! To avoid possible injury or death due to electrical 
shock, open the power supply disconnect switch and secure it 
in an open position during installation.
CAUTION!
CAUTION! Use only copper conductors for field installed 
electrical wiring. Unit terminals are not designed to accept 
other types of conductors.
SAFETY WARNING
High voltage is used to operate this equipment. Failure to observe standard electrical safety procedures may result 
in serious injury. Only persons qualified and / or properly trained should attempt to install, operate and maintain this 
equipment. These chillers come fully charged with refrigerant. Installation, and start – up should be accomplished by 
technicians who are fully certified to handle refrigerants, as required by 40 CRF Part 82, subpart F of the Recycling 
and Emissions Reduction Act. Scroll compressors are used in this equipment. Phase verification is required for proper 
rotation direction. Incorrect rotation will result in elevated sound and internal overload trip failure. 
ATTENTION INSTALLER
3 Phase Scroll Compressor Units
t *GUIJTVOJUVTFTB1IBTF4DSPMM$PNQSFTTPS UIFGPMMPXJOH
JOTUSVDUJPOT
MUST BEGPMMPXFE
6OJUQPXFSTVQQMZ
MUST BEXJSFEJOUIFQSPQFSTFRVFODFUPBWPJE
EBNBHFUPUIF1IBTF4DSPMM$PNQSFTTPS
4DSPMM$PNQSFTTPSTXJUI
INCORRECT SPUBUJPOTIPXUIFGPMMPXJOH
DIBSBDUFSJTUJDT
 )JHITPVOEMFWFM
 )JHITVDUJPOQSFTTVSFBOEMPXEJTDIBHFQSFTTVSF
 -PXDVSSFOUESBX
*GBOZPGUIFUISFFBCPWFDIBSBDUFSJTUJDTFYJTU TXBQUXPPGUIF
UISFFTVQQMZXJSFTBUUIFEJTDPOOFDUBOESFDIFDLDPNQSFTTPSGPS
JODPSSFDUSPUBUJPO