background image

2. Hold the B key down and press the S key successively to

choose the forcing desired.

Display

Back-up

m + d

Forcing additional heating for heating

m + r

Forcing additional heating for DHW

m + d + r

Forcing additional heating for heating and

DHW

The m symbol disappears from
the display

Additional heating forcing deactivated

4.3.5.

Hybrid operating mode

CAUTION

The hybrid operating mode is only available for appliances

with hydraulic back-up.

The appliance offers a choice between several hybrid operating

modes. The modes available offer either optimised energy

consumption according to energy cost, or optimised energy

consumption according to primary energy consumption. Both hybrid

operating modes are available via parameter U1. In optimised

primary energy consumption mode, the control system chooses the

generator that consumes the least primary energy. In optimised

energy cost mode, the control system chooses the cheapest

generator according to the coefficient of performance of the heat

pump and according to energy cost.
To access the parameters:
1. Press the ¿ key 3 times.

2. The symbol $ flashes.

Press the key ® to enter the "Installer" menu.

3. Use the + and - keys to switch from one parameter to another.
4. Use the + and - keys to change the parameter value.

Press the ® key to confirm the setting.

To modify another parameter, repeat the procedure from

step 3.