Manual venting, Automatic venting – DE DIETRICH ALEZIO AWHP MIV-II User Manual

Page 24

Advertising
background image

5.4.1.

Manual venting

1. Open the valves on all radiators connected to the heating system.
2. Put the heat pump in shutdown/frost protection mode.

¼ "Changing the operating mode", page 18

3. Vent the underfloor heating circuits and the radiators. First vent

the lower floors A and then the upper floors Z.

5.4.2.

Automatic venting

The heat pump runs an automatic venting cycle when it is powered

up. Automatic venting takes approximately one minute.

If a DHW tank is connected to the heat pump:

Automatic venting starts up only if the measured DHW

temperature is lower than 25°C.

It is possible to extend automatic venting manually to run for more

than one minute:
1. The word SERVICE flashes when powering up. Press

the SERVICE key.

a venting cycle begins. The word SERVICE stops flashing .

2. Press the SERVICE key to stop the venting cycle.

¼Consult the installer for more detailed information.

WARNING

After venting, check whether the pressure in the

installation is still sufficient. Add water to the installation if

necessary.
¼See chapter: "Top up the installation with water",

page 22