DE DIETRICH ALEZIO AWHP MIV-II User Manual
Page 29
AWHP-II
4 MR
6 MR
8 MR
11 MR 11 TR
14 MR 14 TR
16 MR 16 TR
Max pre-loaded length
m
30
30
30
30
30
30
30
30
30
Weight (empty) - Outside module kg
45
45
75
121
135
116
130
116
130
Weight (empty) - Indoor module
kg
35
35
35
37
37
37
37
37
37
(1) Hot mode: Outside air temperature +7 °C, Water temperature at the outlet +35 °C. Performances in line with EN 14511-2.
(2) Hot mode: Outside air temperature +2 °C, Water temperature at the outlet +35 °C. Performances in line with EN 14511-2.
(3) Only in reversible versions
(4) Cooling mode: Outside air temperature +35 °C, Water temperature at the outlet +18 °C. Performances in line with EN 14511-2
(5) 5 m from the appliance, free field.
(6) Noise spread by the envelope - Test conducted in accordance with the standard NF EN 12102
AWHP MIV-II
7. Technical specifications
23/04/2013 - 300023321-001-03
28