Parameter Description

Adjustment range

Factory setting
MCA
45 65 90 115

p6

Display screen

Do not modify

2

2

2

2

p7

Post-circulation of the boiler pump connected to the PCU 1 to 98 minutes

99 minutes = continuous

3

3

3

3

p8

Brightness of display lighting

Do not modify

1

1

1

1

5.3.2.

Modification of the user-level parameters

Parameters p1 to p8 can be modified by the user in order to meet

central heating and DHW comfort needs.

CAUTION

Modification of the factory settings may be detrimental to

the functioning of the appliance.

1. Press the two keys f simultaneously and then key [+] until the

symbol W flashes on the menu bar.

2. Select the users menu using the key S. p[1 is displayed with

1 flashing.

3. Press the S key a second time. The value 80°C appears and

flashes (for example).

4. Change the value by pressing the [-] or [+] key. In this example

using key [-] to 60°C.

5. Confirm the value with the S key. p[1 is displayed with 1

flashing.

6. Press the j key 2 times to return to the current operating mode.

4

The parameters p2 to p8 are changed in the

same way as p1. After step 2, use the [+] key to

move to the required parameter.

4

The parameters p1 (the maximum heating water

temperature) and p2 (the maximum drinking water

temperature) can also be modified using the quick

selection menu.

M

"

bar

C0

030

50-

A









1x

2x

MCA 45 - 65 - 90 - 115

5. Operating the appliance - IniControl

28/08/12 - 300024828-001-01

32