background image

Code Faults

Cause
of the
fault

Description

Checking / solution

D32

5 RESET:ON/OFF

SCU

5 resets done in less than an hour

4

Switch the boiler off and switch back on

4

If the boiler does not start after several resets (5 attempts possible), contact your

heating engineer and inform him of the error message displayed

D37

TA-S SHORT-CIR

SCU

The Titan Active System® is short-circuited

4

Contact the professional who takes care of maintenance of the appliance

Remarks:

Domestic hot water production has stopped but can nonetheless be restarted using key
r

.

The tank is no longer protected.

If a tank without Titan Active System® is connected to the boiler,check that the TAS

simulation connector (delivered with package AD212) is fitted to the sensor card.

D38

TA-S DISCONNEC

SCU

The Titan Active System® is on an open circuit

4

Contact the professional who takes care of maintenance of the appliance

Remarks:

Domestic hot water production has stopped but can nonetheless be restarted using key
r

.

The tank is no longer protected.

If a tank without Titan Active System® is connected to the boiler,check that the TAS

simulation connector (delivered with package AD212) is fitted to the sensor card.

D99

DEF.BAD PCU

SCU

The SCU software version does not recognise the PCU connected

4

Contact the professional who takes care of maintenance of the appliance

MCA 45 - 65 - 90 - 115

7. Troubleshooting