STEP 4: (ELECTRIC DRYER ONLY)

Connect Electrical Plug

For further assistance, refer to Section on Electrical
Requirements
.

IMPORTANT: Use only a new U.L. listed No. 10
(copper wire only) three conductor power supply cord
kit rated 240 Volts (minimum) 30 Amperes and
labeled as suitable for use in a clothes dryer.

NOTE: For more detailed information on connecting
three-wire or four-wire plugs, refer to Section on
Electrical Plug Connection
.

NOTE: Four-wire cord is required for mobile homes
or where codes do not permit grounding through
neutral.

STRAIN

RELIEF

NUT

TYPICAL

THREE-WIRE

RECEPTACLE

POWER CORD

(Three-Wire)

STRAIN

RELIEF

D275IE0D

Three Wire

Three Wire

NUT

TYPICAL

FOUR-WIRE

RECEPTACLE

POWER CORD

(Four-Wire)

STRAIN

RELIEF

D006IE0A

STRAIN

RELIEF

Four Wire

D276IE1A

CENTER

WIRE

(NEUTRAL)

STRAIN

RELIEF

(NOT SUPPLIED

WITH DRYER)

NEUTRAL

TERMINAL

GROUND

WIRE

"L2"

TERMINAL

"L1"

TERMINAL

GROUND

SCREW

GROUND

TO NEUTRAL

WIRE

Three-Wire Connection

D171IE1A

WHITE

WIRE

(NEUTRAL)

GROUND

SCREW

NEUTRAL

TERMINAL

"L1"

TERMINAL

BLACK

WIRE

GROUND

WIRE

STRAIN

RELIEF

(NOT SUPPLIED

WITH DRYER)

GROUND

WIRE

"L2"

TERMINAL

RED

WIRE

Four-Wire Connection

NOTE: Dryer is shown with access cover removed for illustration purposes only. NEVER operate dryer with