Electrical Requirements . . .

(Gas Dryers)

(120 Volt, 60 Hertz, With 3-Prong Grounding Plug)

NOTE: The wiring diagram is located behind the
control panel, inside the control cabinet.

• Each dryer is designed to be operated on a separate

branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current) circuit
protected by a 15 ampere fuse, equivalent fusetron or
circuit breaker.

• The three-prong grounding plug on the power cord

should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 120 Volts AC
(alternating current) 15 Amps. See illustration below
for determining correct polarity of the wall receptacle.

NOTE: A qualified electrician should check the
polarity of the wall receptacles. If a voltage reading is
measured other than that illustrated, the qualified
electrician should correct the problem.

• DO NOT OPERATE OTHER APPLIANCES ON THE

SAME CIRCUIT WHEN THIS APPLIANCE IS
OPERATING. DO NOT OVERLOAD CIRCUITS!

See illustration below.

\

To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of the
National Electrical Code ANSI/NFPA 70 or the
Canadian Electrical Code, CSA C22.1, and
such local regulations as might apply. It is
the customer’s responsibility to have the
wiring and fuses checked by a qualified
electrician to make sure the laundry room
has adequate electrical power to operate the
dryer.

W035

WARNING

This dryer is equipped with a three-prong
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.

W036

WARNING

D009IE0B

DO NOT

OVERLOAD

CIRCUITS

To reduce the risk of an electric shock or fire,
DO NOT use an extension cord or an adapter
to connect the dryer unit to the electrical
power source.

W152

WARNING

D090IE1B

STANDARD

120 VOLT,

60 HERTZ,

3-WIRE EFFECTIVELY

GROUNDED CIRCUIT

NEUTRAL

SIDE

ROUND

GROUNDING

PRONG

GROUND

NEUTRAL

L1

0

V.A.C.

115

±

12

V.A.C.

115

±

12

V.A.C.