12

Option: Maximum stroke limitation

7.2.

Actuators G-100, H-125

Loctite 274

Parts required

1 Threaded nipple

2 Setscrew M12 x 1.5

3 Nut M12 x 1.5

4 Nut

5 O-ring (actuator)

6 Acutator cover

(actuator)

7 Sleeve (actuator)

8 Disk (actuator)

Fig. 4: Actuators G-100, H-125,

maximum stroke limitation without position repeater

7.2.1. Work to be carried out before

installation

DANGER!

Hazard due to high pressure!
• Interrupt the control air and fluid infeed before modifying the

devices and reduce the pressure in the fluid system.

→

Interrupt supplies of control air and medium.

→

Empty valve housing.

→

Unscrew transparent cap from actuator cover

⑥.

→

Screw out position indicator with Allan key (WAF8).

NOTE!

Damage to the actuators due to incorrect tool!
• Only the special wrench provided by Bürkert for the purpose

must be used to screw down the actuator cover.

• (see chapter on assembly accessories).

→

Screw off actuator cover

⑥ with special wrench, counterbracing

at the sleeve.