Burkert Type 2033 User Manual

Page 20

Advertising
background image

20

Option: Min. /max. stroke limitation

WARNING!

Risk of injury and functional failure due to derailed or slipped
parts!
The actuators contain pre-tensioned springs that may derail or slip
on improper opening.
• Actuators K-175 and L-225 shall only be opened in our factory

or by the responsible distributor.

8.3.1. Work to be carried out before

installation

DANGER!

Hazard due to high pressure!
• Interrupt the control air and fluid infeed before modifying the

devices and reduce the pressure in the fluid system.

Interrupt supply of medium and empty valve housing.

Bring actuator into the upper piston position.

DANGER!

For control function A and I:
Risk due to high pressure when screwing on the visibility
hood!
The visibility hood must not be pressurized during attachment.
• Therefore pressurize only the lower piston area via the lower

control air connector using compressed air.

Unscrew transparent cap from actuator cover.

Screw out position indicator/spindle cap
( yellow screw cap; see “

Fig. 8: “) by hand.

Interrupt supply of control air.

8.3.2. Installation and commissioning

Lightly grease spindle extension

(silicone grease OKS 1110-0).

Screw spindle extension

① (with Allan key WAF8) onto actuator

spindle (M16x1.5) and secure with Loctite 274.

Place guide spindle

② over spindle extension ①.

Type 2012 Control Function A:

Screw stop

⑧ onto guide spindle ② and secure with

Loctite 274.

Stop length for Actuator K-175 (2012):

54.5 mm

Stop length for Actuator L-225 (2012):

44 mm