Burkert Type 2033 User Manual

Page 20

Advertising
background image

20

Option: Min. /max. stroke limitation

WARNING!

Risk of injury and functional failure due to derailed or slipped
parts!
The actuators contain pre-tensioned springs that may derail or slip
on improper opening.
• Actuators K-175 and L-225 shall only be opened in our factory

or by the responsible distributor.

8.3.1. Work to be carried out before

installation

DANGER!

Hazard due to high pressure!
• Interrupt the control air and fluid infeed before modifying the

devices and reduce the pressure in the fluid system.

→

Interrupt supply of medium and empty valve housing.

→

Bring actuator into the upper piston position.

DANGER!

For control function A and I:
Risk due to high pressure when screwing on the visibility
hood!
The visibility hood must not be pressurized during attachment.
• Therefore pressurize only the lower piston area via the lower

control air connector using compressed air.

→

Unscrew transparent cap from actuator cover.

→

Screw out position indicator/spindle cap
( yellow screw cap; see “

Fig. 8: “) by hand.

→

Interrupt supply of control air.

8.3.2. Installation and commissioning

→

Lightly grease spindle extension

①

(silicone grease OKS 1110-0).

→

Screw spindle extension

① (with Allan key WAF8) onto actuator

spindle (M16x1.5) and secure with Loctite 274.

→

Place guide spindle

② over spindle extension ①.

Type 2012 Control Function A:

→

Screw stop

⑧ onto guide spindle ② and secure with

Loctite 274.

Stop length for Actuator K-175 (2012):

54.5 mm

Stop length for Actuator L-225 (2012):

44 mm

english

Type 2000, 2002, 2012

2030, 2031; 2032, 2033

Advertising
This manual is related to the following products: