25

Option: Electrical position repeater

10.2. Actuators G-100, H-125

Parts required

1 Electrical position repeater

with appliance socket

2 Adapter

3 Threaded sleeve

(only for Types 2030,2031)

Fig. 13: Actuators G-100, H-125 with electrical position repeater

10.2.1. Work to be carried out before

installation

DANGER!

Hazard due to high pressure!
• Interrupt the control air and fluid infeed before modifying the

devices and reduce the pressure in the fluid system.

Interrupt supply of medium

Empty valve housing.

Bring actuator into the upper piston position.

DANGER!

For control function B and I:
Risk due to high pressure when screwing on the visibility
hood!
The visibility hood must not be pressurized during attachment.
• Therefore pressurize only the lower piston area via the lower

control air connector using compressed air.

Unscrew transparent cap from actuator cover.

Screw off position indicator with Allan key (WAF8).

Type 2030, 2031: Screw threaded sleeve

③ onto actuator

spindle (WAF14).

Then interrupt supply of control air.

10.2.2. Installation and commissioning

Screw adapter

② instead of transparent cap onto actuator

(see “

Fig. 13: Actuators G-100, H-125 with electrical position

repeater”).

Screw electrical position repeater

① into adapter ②

(see “

Fig. 13: Actuators G-100, H-125 with electrical position

repeater”).