Assembly

Type 2036

8.

asseMBly

8.1.

safety instructions

Danger!

risk of injury from high pressure in the equipment/device.

▶ Before working on equipment or device, switch off the pressure

and deaerate/drain lines.

Warning!

risk of injury from improper assembly.

▶ Installation must only be carried out by authorized technicians

and with the appropriate tools.

risk of injury from unintentional activation of the system and
uncontrolled restart.

▶ Secure system from unintentional activation.

▶ Following assembly, ensure a controlled restart.

8.2.

Before installation

→

Before connecting the valve, ensure the pipelines are flush.

→

Pay attention to the flow direction.

8.2.1. installation position

• The piston-controlled diaphragm valve can be installed in any

position, preferably with connection B downwards.

• Installation for self-drainage of the body:

see chapter "5.4. Valve self-draining"

8.2.2. preparatory work

→

Clean pipelines (sealing material, swarf, etc.).

→

Support and align pipelines.

devices with welded body

note!

damage to diaphragm or actuator.

▶ Before welding in the body disassemble the actuator and

diaphragm.

Remove the actuator from the valve body:

→

Move the actuator to the upper actuator position (CFA, NC: by
applying pilot pressure; CFB, NO: by removing the pilot pressure).

→

Mark the position of the actuator in relation to the valve body.

→

Unscrew the four body screws that connect the valve body with
the actuator. Remove the actuator and the diaphragm.

english