Basicsafetyinstructions

Type 2036

further instructions:

▶ The user must ensure that the appliance is used in Zone 1/21 or

2/22 only.

▶ The control unit may restrict use in an explosive atmosphere. Follow

operating instructions for control unit.

▶ Check that any cleaning agents are approved for use in explosive

atmospheres.

3.1.2. Media temperature

Danger!

▶ If explosive media are used this can cause additional explosion risks.

▶ If media temperatures are used between 130 °C and 150 °C, the

temperature class T3 / 200 °C applies (dust).

Media temperature

max. 130 °C

3.1.3. Marking ex area

ptB 13 ateX d103 X
ii 2g c iic t4
ii 2d c t135°c

Warning: not valid when non-ex devices added.

do not open actuator. spring loaded cover.

Fig. 1: Marking Ex area

The Ex marking is not valid if Non-Ex devices are added.

3.2.

special conditions

→

To ensure potential equalization, ground the valve body to the
pipe system using an electrically conductive connection.

Danger!

danger of explosion caused by electrostatic charge.
In the event of a sudden discharge from electrostatically charged
devices or individuals there is a risk of an explosion in the Ex area.

▶ Implement suitable measures to ensure that there are no

electrostatically charges in the Ex area (see also "3.1. Use in Ex

area").

▶ Clean the device surface by gently wiping it with a damp or anti-

static cloth only.

▶ Earth the actuator and valve body.

▶ If a plastic body is used, earth the actuator separately.

Ambient temperature range: 0 °C ≤ Tamb ≤ 60 °C