Burkert Type 2036 User Manual

Page 8

Advertising
background image

8

Basicsafetyinstructions

Type 2036

further instructions:

▶ The user must ensure that the appliance is used in Zone 1/21 or

2/22 only.

▶ The control unit may restrict use in an explosive atmosphere. Follow

operating instructions for control unit.

▶ Check that any cleaning agents are approved for use in explosive

atmospheres.

3.1.2. Media temperature

Danger!

▶ If explosive media are used this can cause additional explosion risks.

▶ If media temperatures are used between 130 °C and 150 °C, the

temperature class T3 / 200 °C applies (dust).

Media temperature

max. 130 °C

3.1.3. Marking ex area

ptB 13 ateX d103 X
ii 2g c iic t4
ii 2d c t135°c

Warning: not valid when non-ex devices added.

do not open actuator. spring loaded cover.

Fig. 1: Marking Ex area

The Ex marking is not valid if Non-Ex devices are added.

3.2.

special conditions

To ensure potential equalization, ground the valve body to the
pipe system using an electrically conductive connection.

Danger!

danger of explosion caused by electrostatic charge.
In the event of a sudden discharge from electrostatically charged
devices or individuals there is a risk of an explosion in the Ex area.

▶ Implement suitable measures to ensure that there are no

electrostatically charges in the Ex area (see also "3.1. Use in Ex

area").

▶ Clean the device surface by gently wiping it with a damp or anti-

static cloth only.

▶ Earth the actuator and valve body.

▶ If a plastic body is used, earth the actuator separately.

Ambient temperature range: 0 °C ≤ Tamb ≤ 60 °C

english

Advertising