Burkert Type 2300 User Manual

Page 10

Advertising
background image

10

Technical data

Typ 2300

WARNING!

Risk of injury from improper installation!
• Installation may be carried out by authorised technicians only and

with the appropriate tools!

Risk of injury from unintentional activation of the system and
an uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.
For control function I – Danger if pilot pressure fails!
For control function I control and resetting occur pneumatically.
If the pressure fails, no defined position is reached.
• To ensure a controlled restart, first pressurize the device with pilot

pressure, then switch on the medium.

Risk of injury from moving parts in the device!
• Do not reach into openings.

8.2. Before installation

• The globe control valve can be installed in any installation position,

preferably with the actuator in upright position.

• Before connecting the valve, ensure the pipelines are flush.
• Make certain the flow direction is correct (flow direction always

below the seat).

8.2.1. Preparatory work

→

Clean pipelines (Sealing material, swarf, etc.).

Devices with welded body
Remove the control unit from the actuator (if present):

→

Clamp the valve body in a holding device.

→

Loosen the fastening screws (2x).

→

Remove the control unit upwards.

Fastening
screw (2x)

Control unit

Actuator

Fig. 2:

Disassembly the control unit

Remove the actuator from the valve body.

→

Install collet (white grommet) in pilot air port 1.

NOTE!

Damage to the seat seal or the seat contour!
• When removing the actuator, ensure that the valve is in open

position.

→

Control function A pressurize the pilot air port 1(see “Fig. 3”)
with compressed air (5 bar): valve opens.

→

Using a suitable open-end wrench, place the wrench flat on the
pipe.

→

Unscrew the actuator from the valve body.