Packaging, transport, storage – Burkert Type 2300 User Manual

Page 15

Advertising
background image

15

Technical data

Typ 2300

Pilot air port

Exhaust air port

Additional exhaust air port only

with pilot-operated control

system for high air output from

(actuator size ø 130)

1

3

3.1

Fig. 8:

Pneumatic connection

Control air hose:

6/4 mm or 1/4” pilot air hoses can be used.
A pilot air port via G 1/8” thread is available as an option.

8.5. Removal

WARNING!

Risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.
• Before removing a device, switch off the pressure and vent the

lines.

Procedure:

Loosen the pneumatic connection.

Remove the device.

8.6. Maintenance work

Complete a visual inspection of the equipment once a year. Shorter
maintenance intervals may be recommended depending on the
operating conditions.

Wear parts: seals and control cone.

In the event of a leak, replace the relevant wear part.

The maintenance and repair instructions are available on the
Internet:

www.burkert.com

9. PACKAGING, TRANSPORT,

STORAGE

NOTE!

Transport and storage damage!
• Protect the device against moisture and dirt in shock-resistant

packaging during transportation and storage.

• Permitted storage temperature: -20 – +65°C.
Damage to the environment caused by device components
contaminated with media.
• Ensure the device and packaging are disposed of in an environ-

mentally sound manner!

english