Burkert Type 2300 User Manual

Page 11

Advertising
background image

11

Technical data

Typ 2300

Actuator

Nipple

Valve body

Flats for open-end

wrench

Pilot air port

CFA, CFB, CFI

Exhaust air port

CFA, CFB

Pilot air port CFI

2

1

Install collet:

Fig. 3:

Installation

Other device versions

Do not remove actuator unless this is a customer-specific
requirement.

Procedure see “Devices with welded body”.

8.3. Installation

WARNING!

Risk of injury from improper installation!
Assembly with unsuitable tools or non-observance of the tight-
ening torque is dangerous as the device may be damaged.
• For installation use an open-end wrench, never a pipe wrench.
• Observe the tightening torque (see “Tab. 5”).

Dirt trap for devices with authorisation in acc. with DIN EN 161
In accordance with DIN EN 161 “Automatic shut-off valves for gas

burners and gas appliances” a dirt trap must be connected upstream
of the valve and prevent the insertion of a 1 mm plug gauge.

8.3.1. Installation of the valve body

Welded bodies

Weld valve body in pipeline system.

Other body versions

Connect body to pipeline.

8.3.2. Install actuator (welded body)

Graphite seal

Fig. 4:

Graphite seal

Check the graphite seal and if required, replace it.

WARNING!

Danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen appli-
cations there is a risk of an explosion!
• In specific applications, e.g. oxygen or analysis applications, use

appropriately authorized lubricants only.

english