The values in the following graphs apply to:
• Stainless steel body (VA) with

OD weld end connection
BS clamp connection

To protect the diaphragm during control function B, preferably
do not select the pilot pressure higher than is required to
switch the medium pressure.

control function B / elastomer diaphragm

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

pilot pressure [bar]

m

edium

pressure

[bar]

ø 80 epdm

DN20

DN25

Fig. 13: Pressure graph, actuator ø 80 mm, control function B,

elastomer diaphragm

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

pilot pressure [bar]

m

edium

pressure

[bar]

ш 100, ш 125 epdm

DN40

DN50

Fig. 14: Pressure graph, actuator ø 100 mm and ø 125 mm,

control function B, elastomer diaphragm

control function B / ptfe diaphragm

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

pilot pressure [bar]

m

edium

pressure

[bar]

ш 80, ш 100, ш 125 ptfe

DN40

DN50

DN20 DN25

Fig. 15: Pressure graph, actuator ø 80 mm, ø 100 mm und

ø 125 mm, control function B, PTFE diaphragm