MainTenance, cleaning

10.1 safety instructions

Danger!

danger – high pressure in the equipment!

▶ Before loosening the lines and valves, turn off the pressure and

vent the lines.

risk of injury due to electrical shock!

▶ Before reaching into the system, switch off the power supply

and secure to prevent reactivation!

▶ Observe applicable accident prevention and safety regulations

for electrical equipment!

Warning!

risk of injury from improper maintenance!

▶ Installation may be carried out by authorized technicians only

and with the appropriate tools!

risk of injury from unintentional activation of the system and
an uncontrolled restart!

▶ Secure system from unintentional activation.

▶ Following maintenance, ensure a controlled restart.

10.2 Maintenance work

10.2.1 actuator

The actuator of the diaphragm control valve is maintenance-free
provided it is used according to these operating instructions.

10.2.2 Wearing parts of the diaphragm

control valve

Parts which are subject to natural wear:
• Seals
• Diaphragm

If leaks occur, replace the particular wearing part with an appro-
priate spare part (see chapter “12 Replacement parts”).

A bulging PTFE diaphragm may reduce the flow.

The replacing of the wearing parts is described in chapter
“11 Repairs”.

10.2.3 inspection intervals

Check diaphragm for wear after maximum 10

5

switching cycles.

Muddy and abrasive media require correspondingly shorter
inspection intervals!