5 removal – Burkert Type 2731 User Manual

Page 23

Advertising
background image

7.4.1 connection of the actuator

control functions a:

Connect the control medium to the lower pilot air port of the
actuator (see “Fig. 19: Pneumatic connection”)

control functions B:

Connect the control medium to the upper pilot air port of the
actuator (see “Fig. 19: Pneumatic connection”)

Silencer
For reducing the exhaust air noise: plug the silencer into the free air
discharge connection (see “Fig. 19: Pneumatic connection”)

If used in an aggressive environment, we recommend
conveying all free pneumatic connections into a neutral
atmosphere with the aid of a pneumatic hose.

Lower pilot air port

Upper pilot air port

Fig. 19: Pneumatic connection

control air hose:
Control air hoses of sizes 6/4 mm or 1/4“ can be used.

7.5

removal

Danger!

risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.

▶ Before removing a device, switch off the pressure and vent the

lines.

procedure:

Loosen the pneumatic connection.

Remove the device.

noTe!

deformation of the diaphragm!

▶ For prolonged storage of the valves, slacken the housing screws.