Technical data

6.7.2 electrical data with aS-interface bus

control

Connections

Circular plug-in connector
(M12 x 1, 4-pole)

Supply voltage

29.5 V – 31.6 V DC
(according to specification)

Outputs
Max. switching capacity

1 W via AS-Interface

Watchdog function

integrated

devices without external supply voltage
Max. power consumption

120 mA

Power consumption input during
normal operation
(after current reduction;
valve + 1 end position reached)

90 mA

devices with external supply voltage
External supply voltage

24 V ± 10 %

The power supply unit must include a secure disconnection in

accordance with IEC 364-4-41 (PELV or SELV)

Max. power consumption

55 mA (after current reduction

≤ 30 mA)

Max. power consumption
from AS-Interface

55 mA

6.7.3 electrical data with Devicenet bus

control

Connections

Circular plug-in connector
(M12 x 1, 5-pole)

Supply voltage

11 V – 25 V

Max. power consumption

< 80 mA

Output
Pull-in current current

≤ 50 mA

Holding current

≤ 30 mA