6.1 conformity

In accordance with the EC Declaration of conformity, the control head
Type 8691 is compliant with the EC Directives.

6.2 Standards

The applied standards on the basis of which compliance with the EC
Directives is confirmed are listed in the EC type examination certificate
and/or the EC Declaration of Conformity.

6.3 operating conditions

Warning!

solar radiation and temperature fluctuations may cause mal-
functions or leaks.

▶ If the device is used outdoors, do not expose it unprotected to

the weather conditions.

▶ Ensure that the permitted ambient temperature does not exceed

the maximum value or drop below the minimum value.

Ambient temperature

see type label

Degree of protection

IP65 / IP67 according to EN 60529
(only if cables, plugs and sockets have
been connected correctly
and in compliance with the exhaust
air concept in chapter “8 Pneumatic
installation”
).

6.4 mechanical data

Dimensions

see data sheet

Housing material

exterior: PPS, PC, VA

Sealing material

exterior: EPDM
interior: NBR

Stroke range of valve spindle:

2 – 28 mm
2 – 47 mm

6.5 Type label

Example:

8691 AS-i 62SI

single act Pilot 3,0

Pmax 7bar

Tamb 0°C - +55°C

Ser.-Nr. 001000

00179024

D-74653

Ingelfingen

W14UN

ce

Identification number

Supply voltage / Control

Max. operating
pressure

Typ

Control function
- Pilot valve

Bar-code

Serial number -
CE mark

Max. ambient
temperature

Fig. 4:

Type label (example)

english

Type 8691