Assembly – Burkert Type 8750 User Manual

Page 18

Advertising
background image

18

Assembly

Typ 8750

9. assembly

9.1. safety instructions

Danger!

risk of injury from high pressure in the equipment/device.

▶ Before working on equipment or device, switch off the pressure

and deaerate/drain lines.

risk of electric shock.

▶ Before reaching into the device, switch off the power supply and

secure to prevent reactivation.

▶ Observe applicable accident prevention and safety regulations for

electrical equipment.

Warning!

risk of injury from improper assembly.

▶ Installation must only be carried out by authorized technicians and

with the appropriate tools.

risk of injury from unintentional activation of the system and
uncontrolled restart.

▶ Secure system against unintentional activation.

▶ Following assembly, ensure a controlled restart.

9.2. before installation

The FMR can be installed in any position, preferably with the
process controller face up.

• To avoid turbulent flows around the pressure sensor, fit an

inlet section upstream of the FMR (dimensions acc. to EN
ISO 5167-1, see “Fig. 5: Inlet sections”, page 10)

• Ensure that the pipelines are correctly lined and are not

twisted. If necessary, pipelines must be suitably attached or
supported.

• Observe flow direction (arrow on valve body).

9.2.1. installation

→

Clean pipelines and joints (sealing material, swarf, etc.).

→

Connect FMR to pipeline.

9.3. pneumatic connection of the

process controller

Danger!

risk of injury from high pressure in the equipment/device.

▶ Before working on equipment or device, switch off the pressure

and deaerate/drain lines.

english

Advertising