Accessories

Typ 8750

17. accessories

designation

order no.

M12 connecting cable, 8-pole,
2 m assembled cable

919061

M12 connecting cable, 4-pole,
5 m assembled cable

918038

M8 connecting cable, 4-pole
5 m assembled cable

92903475

USB adapter for connection to a PC in con-
junction with an extension cable

227093

Communications software based on FDT/
DTM technology

Information at

www.burkert.com

Tab. 38: Accessories

18. shuTdoWn

18.1. disassembly

Danger!

risk of injury from high pressure in the equipment/device.

▶ Before working on equipment or device, switch off the pressure

and deaerate/drain lines.

risk of electric shock.

▶ Before reaching into the device, switch off the power supply and

secure to prevent reactivation.

▶ Observe applicable accident prevention and safety regulations for

electrical equipment.

Warning!

risk of injury from improper removal.

▶ Removal may be carried out by authorized technicians only and

with the appropriate tools.

→

Remove electrical connections on the process controller.

→

Release the pneumatic connection on the process controller.

→

Remove FMR from pipeline.

english