Operatingandfunctions

Process level (the digital inputs DI1, DI2 and DI3 are deactivated).

→

To choose the dosing quantity from the memory, activate the digital inputs DI1,
DI2, DI3:

State of input DI3

0

0

0

1

1

1

1

State of input DI2

0

1

1

0

0

1

1

State of input DI1

1

0

1

0

1

0

1

Associated quantity

V1

V2

V3

V4

V5

V6

V7

→

To go back to the Process level, deactivate the 3 digital inputs DI1 to DI3.

The display alternately shows the called memory and the dosing quantity.

→

To start the dosing, send a pulse on the digital input DI4.

V1

00120 L

The dosing quantity is counted down (the dosing units blink).

→

To read the flow rate measured in the pipe, press

or

0......9

.

→

To read the total dosing quantity, press

or

0......9

once.

→

To interrupt the dosing, see “Figure 43”.

00117 L

1156 L

When the dosing is finished, the device is ready for a new dosing.

V1

Figure 42:

Doing a dosing of a quantity from the memory, in dosing mode "EXT. MEM."

English

Type 8025 - 8035 BATCH