Burkert Type 8035 User Manual

Page 71

Advertising
background image

69

Operatingandfunctions

The activation duration of the digital input DI1 is counted even if the dosing has been interrupted.

→

To interrupt the dosing, press

ENTER

: the valve connected to output DO2 and possibly the valve connected

to output DO3 close, the device state LED flashes at a 1 Hz-frequency and the DO4 output (if configured to
transmit the device state, see chap. “9.7.26”) generates a 1 Hz-frequency.

CONtiNUE

RESEt

→

To continue the dosing via the digital inputs:

• let the digital inputs DI2 and DI3 deactivated,

• then send a pulse on DI4.

→

To continue the dosing via the navigation keys, when the digital inputs DI2 and DI3 are
deactivated:

• display "CONTINUE" by pressing key

0......9

or

,

• then press key

ENTER

.

→

To abort the dosing via the digital inputs:

• activate one of the digital inputs DI2 or DI3,

• then send a pulse on DI4.

→

To abort the dosing via the navigation keys, when the inputs DI2 and DI3 are deactivated:

• display "RESET" by pressing key

0......9

or

,

• then press key

ENTER

.

113 L

The counting of the dosing quantity continues.

Process level: the device is ready for a new dosing.

Figure 48:

Interrupting the dosing, in dosing mode "EXT. [T]"

English

Type 8025 - 8035 BATCH

Advertising
This manual is related to the following products: